Development length of a reinforcing bar in compression, to CSA A23.3-19 Cl. 12.3. Calculate the development length of a reinforcing bar in compression per CSA A23.3-19 Cl. 12.3, the edition NBC 2020 references. The basic length is 0.24 d_b f_y / sqrt(f'c), not less than 0.044 d_b f_y, with sqrt(f'c) capped at 8 MPa. A spiral of 6 mm or more at a pitch of 100 mm or less, or 10M or larger ties to Cl. 7.6.5 at 100 mm or less, multiply it by 0.75, and so does the ratio of steel required to steel provided where there is more than analysis needs (Cl. 12.3.3). The result is never taken as less than 200 mm. The same calc to CSA A23.3-24 is the Compression development length page.

First report free, then a free sign-in

critical section db = 16.0 mm ld = 307 mm
Straight bar embedded past the critical section, drawn from the values above.

Given

Jump to results

Type any value, everything below recomputes. Hover or tap a symbol to trace it.

changed from the declared value fcf_{c} MPa\mathrm{MPa}20-80
changed from the declared value fyf_{y} MPa\mathrm{MPa}300-500
changed from the declared value
changed from the declared value
changed from the declared value ss mm\mathrm{mm}25-1,000
changed from the declared value As,ratioA_{s,\mathrm{ratio}} 0.1-1
changed from the declared value

Title block

Optional. Printed in the title block of the PDF.

Results

Quantity Description Value Unit
ld\htmlClass{sym-l_d}{l_{d}} Development length required in compression 307.2 mm\mathrm{mm}

Development length required in compression, in mm\mathrm{mm}, for every bar size against concrete compressive strength, fc′f'_{c} with the other inputs as entered. Bold: 15M at 25 MPa25\ \mathrm{MPa}, whose derivation is below.

Bar size25 MPa25\ \mathrm{MPa}30 MPa30\ \mathrm{MPa}35 MPa35\ \mathrm{MPa}40 MPa40\ \mathrm{MPa}45 MPa45\ \mathrm{MPa}50 MPa50\ \mathrm{MPa}
10M217200ab200ab200ab200ab200ab
15M307.2281.6a281.6a281.6a281.6a281.6a
20M374.4343.2a343.2a343.2a343.2a343.2a
25M483.8443.5a443.5a443.5a443.5a443.5a
30M574.1526.2a526.2a526.2a526.2a526.2a
35M685.4628.3a628.3a628.3a628.3a628.3a
45M839769.1a769.1a769.1a769.1a769.1a
55M1083992.6a992.6a992.6a992.6a992.6a
  1. ldbl_{\mathrm{db}} at its 0.044 dbfy0.044\, d_{b} f_{y} floor, Cl. 12.3.2
  2. Single-bar ldl_{d} at the 200 mm minimum of Cl. 12.3.1, before the bundle factor
Also worth checking
  • Compression lap splice lengths: Cl. 12.16.1 sets the lap by its own rule, and Cl. 12.16.2 takes this development length for the larger of two bar sizes; neither is given
  • End bearing splices (Cl. 12.16.4) and welded or mechanical connections in compression (Cl. 12.16.3)
  • The excess reinforcement ratio of Cl. 12.3.3 a) is taken as entered; that the steel provided exceeds that required by analysis is not checked
  • The 0.75 factor of Cl. 12.3.3 b) takes the spiral or ties as entered: that the spiral is at least 6 mm in diameter, or the ties are 10M or larger ties of a compression member to Cl. 7.6.5 (not, for example, a footing dowel), is not checked
  • That the spiral or ties enclose the bar along the whole of l_d is not checked, Cl. 12.3.3 b)
  • Mechanical anchorage in compression, Cl. 12.1.1 and 12.6.1
  • The bundle limits of Cl. 7.4.2.1 and 7.4.2.2
  • Hooks do not develop a bar in compression (Cl. 12.1.1 and 12.5.5)

Derivation

1.1Bar diameter
db=16 mm(Bar diameter | 15M)\begin{aligned} \htmlClass{sym-d_b}{d_{b}} &= 16\ \mathrm{mm} \quad \left(\text{Bar diameter | 15M}\right) \end{aligned}
1.2Root of concrete strength, capped

Cl. 12.1.2

fc,root=min⁡(fc⋅1 MPa,8 MPa)=min⁡(25 MPa⋅1 MPa,8 MPa)=5 MPa\begin{aligned} \htmlClass{sym-f_c_root}{f_{c,\mathrm{root}}} &= \min\left(\sqrt{\htmlClass{sym-f_c}{f_{c}} \cdot 1\ \mathrm{MPa}}, 8\ \mathrm{MPa}\right) \\ &= \min\left(\sqrt{\htmlClass{sym-f_c}{25\ \mathrm{MPa}} \cdot 1\ \mathrm{MPa}}, 8\ \mathrm{MPa}\right) \\ &= 5\ \mathrm{MPa} \end{aligned}
1.3Tie or spiral factor
kconf=1(No spiral or ties | Cl. 12.3.3 b))\begin{aligned} \htmlClass{sym-k_conf}{k_{\mathrm{conf}}} &= 1 \quad \left(\text{No spiral or ties | Cl. 12.3.3 b)}\right) \end{aligned}
2.1Basic development length

Cl. 12.3.2

ldb=max⁡(0.24⋅db⋅fyfc,root,0.044⋅db⋅fy1 MPa)=max⁡(0.24⋅16 mm⋅400 MPa5 MPa,0.044⋅16 mm⋅400 MPa1 MPa)=307.2 mm\begin{aligned} \htmlClass{sym-l_db}{l_{\mathrm{db}}} &= \max\left(\frac{0.24 \cdot \htmlClass{sym-d_b}{d_{b}} \cdot \htmlClass{sym-f_y}{f_{y}}}{\htmlClass{sym-f_c_root}{f_{c,\mathrm{root}}}}, \frac{0.044 \cdot \htmlClass{sym-d_b}{d_{b}} \cdot \htmlClass{sym-f_y}{f_{y}}}{1\ \mathrm{MPa}}\right) \\ &= \max\left(\frac{0.24 \cdot \htmlClass{sym-d_b}{16\ \mathrm{mm}} \cdot \htmlClass{sym-f_y}{400\ \mathrm{MPa}}}{\htmlClass{sym-f_c_root}{5\ \mathrm{MPa}}}, \frac{0.044 \cdot \htmlClass{sym-d_b}{16\ \mathrm{mm}} \cdot \htmlClass{sym-f_y}{400\ \mathrm{MPa}}}{1\ \mathrm{MPa}}\right) \\ &= 307.2\ \mathrm{mm} \end{aligned}
2.2Development length, single bar

Cl. 12.3.1 and 12.3.3

ld,single=max⁡(ldb⋅kconf⋅As,ratio,200 mm)=max⁡(307.2 mm⋅1⋅1,200 mm)=307.2 mm\begin{aligned} \htmlClass{sym-l_d_single}{l_{d,\mathrm{single}}} &= \max\left(\htmlClass{sym-l_db}{l_{\mathrm{db}}} \cdot \htmlClass{sym-k_conf}{k_{\mathrm{conf}}} \cdot \htmlClass{sym-A_s_ratio}{A_{s,\mathrm{ratio}}}, 200\ \mathrm{mm}\right) \\ &= \max\left(\htmlClass{sym-l_db}{307.2\ \mathrm{mm}} \cdot \htmlClass{sym-k_conf}{1} \cdot \htmlClass{sym-A_s_ratio}{1}, 200\ \mathrm{mm}\right) \\ &= 307.2\ \mathrm{mm} \end{aligned}
2.3Bundle factor
kbundle=1(Single bar | Cl. 12.4)\begin{aligned} \htmlClass{sym-k_bundle}{k_{\mathrm{bundle}}} &= 1 \quad \left(\text{Single bar | Cl. 12.4}\right) \end{aligned}
2.4Development length

Cl. 12.4

ld=ld,single⋅kbundle=307.2 mm⋅1=307.2 mm\begin{aligned} \htmlClass{sym-l_d}{l_{d}} &= \htmlClass{sym-l_d_single}{l_{d,\mathrm{single}}} \cdot \htmlClass{sym-k_bundle}{k_{\mathrm{bundle}}} \\ &= \htmlClass{sym-l_d_single}{307.2\ \mathrm{mm}} \cdot \htmlClass{sym-k_bundle}{1} \\ &= 307.2\ \mathrm{mm} \end{aligned}

Report

Sheet 1 and the first sheet of the working of the PDF report, at the declared values with a sample title block. First report free, then a free sign-in.

Show the two sheets
Sheet 1 of the Compression development length (A23.3-19) report: title block, verdict, checks and figures
Sheet 1: title block, verdict, checks, figures · full size
The first sheet of the working in the Compression development length (A23.3-19) report: each step with its clause
The working: each step with its clause · full size

Questions

Should I use CSA A23.3-19 or A23.3-24?

Use the edition your building code references. NBC 2020 references CSA A23.3-19. A provincial code may differ, so check the one that governs the project. The Edition select on the code line opens the same case under the other edition.

Why is l_db usually the 0.044 d_b f_y floor?

Cl. 12.3.2 takes l_db as 0.24 d_b f_y / sqrt(f'c), but not less than 0.044 d_b f_y. The floor governs once sqrt(f'c) passes 0.24 / 0.044 = 5.45, that is above about 29.75 MPa, so in most concrete the length no longer shortens as f'c rises.

When does k_conf take 0.75?

Cl. 12.3.3 b) gives 0.75 to a bar enclosed within a spiral of at least 6 mm diameter at a pitch of 100 mm or less, or within 10M ties to Cl. 7.6.5 at 100 mm or less. Choose the spiral or the ties and enter s; at more than 100 mm the factor stays 1.0.

How do A_s_ratio and k_bundle change l_d?

Cl. 12.3.3 a) lets l_db be multiplied by A_s required over A_s provided where there is more steel than analysis needs, and the 200 mm minimum of Cl. 12.3.1 applies after it. Cl. 12.4 then lengthens each bar of a bundle by 10, 20 or 33 per cent for two, three or four bars.

Revision history

feat(examples): development length calcs to CSA A23.3-19, published
ValueWasNowUnit
A_tr200mm2\mathrm{mm}^{2}