Compression development length (A23.3-19)
CSA A23.3-19Verified against CSA A23.3-19: 6 formulas and 4 clauses compared with the code text, 1 row from definitions, statics and tablesDevelopment length of a reinforcing bar in compression, to CSA A23.3-19 Cl. 12.3. Calculate the development length of a reinforcing bar in compression per CSA A23.3-19 Cl. 12.3, the edition NBC 2020 references. The basic length is 0.24 d_b f_y / sqrt(f'c), not less than 0.044 d_b f_y, with sqrt(f'c) capped at 8 MPa. A spiral of 6 mm or more at a pitch of 100 mm or less, or 10M or larger ties to Cl. 7.6.5 at 100 mm or less, multiply it by 0.75, and so does the ratio of steel required to steel provided where there is more than analysis needs (Cl. 12.3.3). The result is never taken as less than 200 mm. The same calc to CSA A23.3-24 is the Compression development length page.
First report free, then a free sign-in
Given
Jump to resultsType any value, everything below recomputes. Hover or tap a symbol to trace it.
Resume your last case ()? Load it
This printed copy omits the derivation. The full report, with every step, is the PDF at https://calc.struct.work/calc/development-length-compression-a23.3-19.pdf.
Results
Development length required in compression, in , for every bar size against concrete compressive strength, with the other inputs as entered. Bold: 15M at , whose derivation is below.
| Bar size | ||||||
|---|---|---|---|---|---|---|
| 10M | 217 | 200ab | 200ab | 200ab | 200ab | 200ab |
| 15M | 307.2 | 281.6a | 281.6a | 281.6a | 281.6a | 281.6a |
| 20M | 374.4 | 343.2a | 343.2a | 343.2a | 343.2a | 343.2a |
| 25M | 483.8 | 443.5a | 443.5a | 443.5a | 443.5a | 443.5a |
| 30M | 574.1 | 526.2a | 526.2a | 526.2a | 526.2a | 526.2a |
| 35M | 685.4 | 628.3a | 628.3a | 628.3a | 628.3a | 628.3a |
| 45M | 839 | 769.1a | 769.1a | 769.1a | 769.1a | 769.1a |
| 55M | 1083 | 992.6a | 992.6a | 992.6a | 992.6a | 992.6a |
- at its floor, Cl. 12.3.2
- Single-bar at the 200 mm minimum of Cl. 12.3.1, before the bundle factor
Also worth checking
- Compression lap splice lengths: Cl. 12.16.1 sets the lap by its own rule, and Cl. 12.16.2 takes this development length for the larger of two bar sizes; neither is given
- End bearing splices (Cl. 12.16.4) and welded or mechanical connections in compression (Cl. 12.16.3)
- The excess reinforcement ratio of Cl. 12.3.3 a) is taken as entered; that the steel provided exceeds that required by analysis is not checked
- The 0.75 factor of Cl. 12.3.3 b) takes the spiral or ties as entered: that the spiral is at least 6 mm in diameter, or the ties are 10M or larger ties of a compression member to Cl. 7.6.5 (not, for example, a footing dowel), is not checked
- That the spiral or ties enclose the bar along the whole of l_d is not checked, Cl. 12.3.3 b)
- Mechanical anchorage in compression, Cl. 12.1.1 and 12.6.1
- The bundle limits of Cl. 7.4.2.1 and 7.4.2.2
- Hooks do not develop a bar in compression (Cl. 12.1.1 and 12.5.5)
Derivation
Report
Sheet 1 and the first sheet of the working of the PDF report, at the declared values with a sample title block. First report free, then a free sign-in.
Questions
Should I use CSA A23.3-19 or A23.3-24?
Use the edition your building code references. NBC 2020 references CSA A23.3-19. A provincial code may differ, so check the one that governs the project. The Edition select on the code line opens the same case under the other edition.
Why is l_db usually the 0.044 d_b f_y floor?
Cl. 12.3.2 takes l_db as 0.24 d_b f_y / sqrt(f'c), but not less than 0.044 d_b f_y. The floor governs once sqrt(f'c) passes 0.24 / 0.044 = 5.45, that is above about 29.75 MPa, so in most concrete the length no longer shortens as f'c rises.
When does k_conf take 0.75?
Cl. 12.3.3 b) gives 0.75 to a bar enclosed within a spiral of at least 6 mm diameter at a pitch of 100 mm or less, or within 10M ties to Cl. 7.6.5 at 100 mm or less. Choose the spiral or the ties and enter s; at more than 100 mm the factor stays 1.0.
How do A_s_ratio and k_bundle change l_d?
Cl. 12.3.3 a) lets l_db be multiplied by A_s required over A_s provided where there is more steel than analysis needs, and the 200 mm minimum of Cl. 12.3.1 applies after it. Cl. 12.4 then lengthens each bar of a bundle by 10, 20 or 33 per cent for two, three or four bars.
Revision history
feat(examples): development length calcs to CSA A23.3-19, published
| Value | Was | Now | Unit |
|---|---|---|---|
A_tr | 200 |